Wincc 75 Sp2 Compatibility List Best < Complete >
For multi-user WinCC Servers, redundant servers, or central archiving, utilize these 64-bit server platforms: Standard and Datacenter editions. Windows Server 2019: Standard and Datacenter editions. Windows Server 2016: Standard and Datacenter editions.
Running SCADA environments in virtual machines (VMs) simplifies backups, disaster recovery, and hardware migration. Siemens supports WinCC V7.5 SP2 on specific hypervisors, provided the guest operating system matches the lists above. VMware vSphere
If you want, I can produce: a) a concise compatibility matrix for your specific hardware/software list, or b) a migration checklist tailored to your plant — tell me which and provide the environment details. wincc 75 sp2 compatibility list best
WinCC 7.5 SP2 can co-exist on the same machine as TIA Portal (versions V13 to V18, at least), but with a critical exception : you cannot install "WinCC Professional" from TIA Portal alongside the classic WinCC 7.5 SP2, as their shared components will conflict. For critical communication with newer S7-1200/1500 CPUs from TIA Portal V17 onwards, your WinCC system must be at Update 4 or higher to support the enhanced TLS security protocols.
, provided Internet Explorer 11 is enabled via Windows Features for internal web components. Windows Server: Standard / Datacenter (64-bit). Standard / Datacenter (64-bit). Standard / Datacenter (64-bit). Database & Software Dependencies Microsoft SQL Server: WinCC V7.5 SP2 requires SQL Server 2016 SP2 (64-bit) For multi-user WinCC Servers, redundant servers, or central
| Component | Supported / Recommended for WinCC 7.5 SP2 | |---|---| | TIA Portal engineering | TIA Portal V15 or V15.1 (WinCC 7.5 SP2 integrates with TIA Portal V15 family) | | Operating Systems (Engineering) | Windows 10 Enterprise LTSC 2019/2021, Windows Server 2019 (see notes) | | Operating Systems (Runtime) | Windows 10 IoT/Enterprise (matching supported versions), Windows Server 2016/2019 for multiuser/Server installations | | SQL Database | Microsoft SQL Server 2016 SP2 / 2017 / 2019 (Express for small projects) — use supported CU for security | | OPC | OPC DA 2.05a via COM, OPC UA client/server via WinCC OA/WinCC Unified connectors; use Siemens OPC UA stacks matching firmware | | Browsers (Web/RT WebUX) | Microsoft Edge (Chromium) up-to-date, Chrome latest stable; Internet Explorer deprecated — check WebUX specifics | | Virtualization | Supported on VMware ESXi/Hyper-V with hardware passthrough for HMI GPU; avoid snapshots of running controllers | | Drivers / Communication | PROFIBUS/PROFINET (S7-1200/1500), Modbus TCP via drivers or protocol converters — use driver versions shipped with SP2 | | Redundancy / High availability | WinCC multi-server + SQL Server cluster supported; follow Siemens HA guidelines and mirrored DB configs | | Antivirus/Hardening | Exclude WinCC project paths, runtime executables; follow Siemens hardening guides | | Additional components | WinCC/WebNavigator/WebUX, WinCC Runtime Advanced, WinCC Unified Gateway — verify specific component versions with SP2 |
Note: Domain Controller configurations are technically possible but heavily discouraged by Siemens due to strict security policy overrides that interfere with WinCC user groups. Microsoft SQL Server Compatibility WinCC 7
(Primarily for WinCC WebNavigator client hosting) Best Practices for WinCC Virtualization:
If you are planning a new greenfield project or migrating from an ancient WinCC 7.0 or 7.3 system, 7.5 SP2 is the best "stable edge" you can currently deploy.