Narishige Pc10 Manual New Here

Place the unit away from air conditioning vents, windows, and heavy foot traffic. Drafts alter filament cooling times, causing inconsistent pipette shapes.

The heater coil will activate, glowing orange as it warms up.

If the heater coil becomes brittle or fails to heat (Error E_99), it must be replaced. Environment:

Achieving reproducible pipettes requires finding the "filament burn limit" for your specific glass capillary dimensions. Step 1: Installing the Glass Capillary Loosen the upper and lower slider clamping knobs. narishige pc10 manual new

Locate the top and bottom slider clamps. Loosen the thumbscrews, slide the glass capillary through the center of the platinum heating coil, and secure it firmly inside both the upper and lower clamping blocks. Ensure the glass is perfectly centered within the loop of the heating coil. Step 3: Configure Your Stages

Allows the user to toggle between a single-stage pull (one heating cycle for blunt, short tapers) and a dual-stage pull (two heating cycles for long, fine-tipped microelectrodes). Main Power Switch: Toggles the system on or off.

Lower the acrylic safety shield. Press the button. The coil will glow, the glass will soften, and gravity will drop the lower clamp to create your micropipettes. 5. Calibration and Finding the Filament Burn Value Place the unit away from air conditioning vents,

Outside, the city stirred. Inside, Lena closed the manual and placed it back in its box, writing in the margin of the title page: “Calibrated 04-09-2026. —L.” It was a notation small as a comma, but in time it would become a lineage, a tiny lineage recorded in pencil on paper, passed down like an instruction and a blessing.

Adjust the to a moderate setting (e.g., 65–75% of max) to soften the glass for the initial taper.

Ensure the main voltage matches the factory specification tag on the rear of the device (typically 100V, 115V, or 230V AC). Operational Safety If the heater coil becomes brittle or fails

She ran a test series—a slow aspirate, a fast dispense, a micro-adjust to find the sweet spot between too slow and too violent. The manual’s charts suggested optimal speeds; Lena found them conservative, affectionate. She skimmed “maintenance” and vowed to clean the seals tonight. The manual ended with a quiet paragraph about responsibility: instruments carried memory, and the lab was a place where those memories mattered.

AC 100V, 120V, 220V, or 240V (factory configured), 50/60Hz. Box Contents Checklist PC-10 Main Puller Unit Acrylic Dust Cover Replacement Platinum Heating Coils (typically 2 units) Standard Weights (for adjusting pull tension) Power Cord and Instruction Sheet 2. Setup and Installation