The gate sounds an alarm, flashes red, and blocks the lane if safety parameters permit.
: Units must be perfectly parallel and correctly aligned to operate properly. 2. Mechanical & Electrical Specifications SpeedStile FL
Use metal shims to ensure the frame is perfectly level if the floor is uneven. 3.4. Electrical Installation gunnebo speedstile fl installation manual
Connect the building’s Fire Alarm Control Panel (FACP) to the dedicated emergency input terminal (normally closed contact). Opening this circuit cuts power directly to the brake or motor matrix, allowing the glass wings to instantly fail-open in the direction of egress. 5. Commissioning, Calibration, and Testing
Ensure the conduits protrude between 30 mm and 50 mm above the finished floor level. Conduit A (Power): 25 mm diameter for AC mains power. The gate sounds an alarm, flashes red, and
Maximum 95% relative humidity, strictly non-condensing.
Check all wiring terminal blocks for loose screw connections caused by building vibration. Opening this circuit cuts power directly to the
Use a laser level or string line to ensure that the front edges, rear edges, and sensor windows of the parallel cabinets are perfectly square and parallel to each other.